SERIAL
CONNECTIONS
1
2
3
4
5
6
7
8
* Current shared with encoder port
Pin Function Note
1 RS485 Data In A Rx+
Serial Port #2
2 RS485 Data In B Rx-
3 RS232 Transmit Serial Port #1
4 0V Servo/Encoder
5 RS232 Receive Serial Port #1
6 5V Output 150mA max*
7 RS485 Data Out Z Tx-
Serial Port #2
8 RS485 Data Out Y Tx+
A standard Ethernet connector is provided for use as
the primary programming interface.
The Trio programming software, Motion Perfect v3,
must be installed on a Windows based PC that is
tted with an Ethernet connection. The IP address is
displayed on the MC4N display for a few seconds after
power-up or when an Ethernet cable is plugged in.
Ethernet cable must be CAT 5 or better.
The Standard Ethernet connection may also be used for
Ethernet-IP, Modbus and other factory communications.
See back page for set-up details.